245T Croaked escaping from work[240-260/1985] posted by Paul S. on
Wednesday, 22 April 1998, at 10:22 a.m.

I started the beast (1985 245 Turbo B21FT, K-jet) as normal yesterday afternoon. A warm day - upper 60's - this is Seattle, Man! Anywho car started fine, turned radio on to AM talk radio, idled for 10 seconds or so, backed out per work instructions. Put her in D and drove maybe 6 feet, hear a loud pop through the radio speakers and car dies!!

So not wanting to be seen in a dead Volvo (everybody at work knows I'm a Volvo junkie by now)I quickly put my mind in hyperdrive - what's wrong?

Loud pop on AM....hmmm electrical....car died suddenly....hemmm electrical alas...check fuses...Ah Hah...main fuel pump fuse blew completely...I mean exploded!! And of course I have many spares (both stainless and old crusty continental style.) Popped in a 16 amp conti style (didn't want to waste my ss fuses - if it imediately blew again!.....but it didn't)

The car started up and runs like a champ!!

This all happened it less than 2-3 minutes, without removing my posterior from the leather to open the hood. While I am thankful/proud of my internet gained troubleshooting ability....and sort of knowing the hassles with that #6 fuse and the fuel pump relay....I still do not know what actually caused the fuse to blow.

Some more useful information.

1) I swapped in all SS fuses first day I got the car. (I still need to go back in and wirebrush/clean the contacts but they look ok - well now the #6 is darkened)

2) By strange coincidence I ordered a new fuel pump relay on Monday, should arrive by Friday!!!

3)On Sunday I was underneath the beast cleaning the sh*t out of the under carraige of the car. (Don't ask - but usually underneath and in the engine bay of my cars are cleaner than the exterior painted surfaces) I sprayed a lot of Simple Green and water around and on the main fuel pump. If this caused a short, why did it wait 'till Tuesday to blow the fuse?

4) When I removed the gas cap to fill the car with petrol for my first time there was a huge vacuum in the fuel tank - more than any car I've owned. (The '81 262C with B28F K jet did not seal the tank like this.) Should this car have a vented gas cap?

Any help would be cool. Should I replace my fuel pump? Or just the relay?

Sorry for being "windy"....sorry....I mean "long"....whoops..for wasting bandwidth...

--
Paul S. (Mr. Project 245T)


Re: 245T Croaked - Fuel Pump Fuse[240-260/1985] posted by Dave Stevens on
Saturday, 25 April 1998, at 4:36 p.m.

I didn't think the 240 fuel pump fuse problems were as bad as the old 140 problems, but yours sounds the same to me so here's all I've learned on the topic.

My basic rule of thumb is if a fuse blows for no good reason then just replace it. If it blows again only then is it time to dig into the problem. Start simple and work up:
-The open ceramic/plastic fuses will oxidize over time, adding resistance which, for a heavily loaded circuit like the fuel pump, will heat the fuse and speed the oxidation until it eventually blows. Caution, the fuel pump fuse can often be hot enough to burn skin. A simple fuse replacement may be all that's needed here. The stainless steel fuses pretty much eliminate this kind of problem.
-The copper fuse holder contacts will similarly become a problem over time. An overheated fuse and repeated replacement will weaken the contact. Any corrosion between the contact and the fuse just makes it all the worse. Discoloration of the copper contact is a dead giveaway. So, keep the contacts clean, pinch them in a little to maintain good contact and use dielectric grease to prevent oxidation. Any moisture in the fuse panel area will hasten this problem, like water leaks from around the windshield or through the kick panel floor vent.
-If a replacement fuse blows instantly then suspect shorted wiring (consider the burnt fuse a time saver). Disconnect the pump to isolate the short to the motor or to wiring. Damaged wire insulation on the pump circuit (like under the rear seat) can lead to intermittent shorts that are hard to find. Trace with an audible DVO meter inspecting and wiggling the wires and connectors as you go.
-If the main fuel pump is getting weak (arthritic), is working too hard (the in-tank pre-pump has failed, the gas line/filter is blocked or the gas cap has created a vacuum seal) then it will draw heavy current and overheat and weaken the fuse eventually blowing it. A noisy pump is often associated with this problem. Although replacing the fuel pump may temporarily solve the problem, if the cause isn't dealt with then you'll be replacing it again sooner rather than later.
-I suppose it's possible for the fuel pump relay to cause these symptoms. You could open it up for a visual inspection, but unless it's obviously corroded or discolored I wouldn't get too excited. Relay problems usually just lead to fuel starvation and rough running.

BTW, you've got K-Jet. For 240's with LH-Jet, the main fuel system 20 amp fuse under the hood and its holder are also chronic electrical problem areas.

Gee, Paul, re. cleaning the underside of your Brick, what kind of wax do you prefer on the drive shaft?




 


©Jarrod Stenberg 1997-2020. All material except where indicated.



Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.