air conditioning leak[740-760/88] posted by pete howell on
Sunday, 16 August 1998, at 11:23 p.m.
The 88 745 GLE has a slow leak (1lb/2 months) How is the best way to find/seal a leak of this type. Any places bricks are known to leak from?
TIA
Re: air conditioning leak[740-760/88] posted by Steve Ringlee on
Monday, 17 August 1998, at 7:44 a.m.
Wow! One pound in two months is more than a slow leak. Take the car to an a/c shop; most have a special leak tester that very accurately finds freon leaks in components. They should not charge more than about $25.
--Steve Ringlee
Re: air conditioning leak[740-760/88] posted by Don Foster on
Monday, 17 August 1998, at 7:45 a.m.
Pete ---
That sounds like more than "a slow leak". When refrigerant leaks out, it takes the oil with it. Look for a buildup of oily dirt around leaking fittings. And don't open the AC system until it has been depressurized!!
--Re: air conditioning leak[740-760/88] posted by Michael Mahler on
Monday, 17 August 1998, at 9:40 a.m.
If it's that BIG a leak, check the high pressure line running along
the frame rail. They rot where they are held down by the metal
fasteners (the ones with rubber grommets that screw down to the rail).
Since you are no doubt going to have to take the system apart to
fix the leak, now is a good time to change to R134. Finding the
leak first (if it's not an obvious one as it was on mine - the
metal line actually corroded in HALF at the point it was being
held down by one of those metal clamps onto the frame) is a
priority. But to do the conversion properly, order new o-rings
for ALL the connections and redo them all, not just the ones the
Volvo kit gives you. I would then consider adding a can that has
dye in it, in case you haven't fixed the leak. If it's the kind
of yellow-green dye that glows under black light, then just
go get a black light at Walmart.
Hose leaks[740-760/88] posted by JohnB on
Monday, 17 August 1998, at 10:23 a.m.
High pressure hose from compressor to condensor is likely culprit...look for oil.
There are also injectable dyes in cans, they go right to suction side of compressor schrader valve...I like the flourescent kind that use black light.
Don't bother to convert to R12 unless you have to replace a compressor.
If this is the first time you've done anything to your ac system, or five years since you've replaced a reciever/dryer or expansion tube/filter, consider replacing the receiver dryer and the expansion tube/filter. Chances are they're both toast/contaminated by now.