BrickBoard Archives
The files contained in this listing have been automatically archived from the active forums. Because the vast majority of posts are now in one place, this archive is considered legacy. You should use the SEARCH feature OR choose your topic and select date tabs within the forum you choose.
240 hard to start[ALL/1988] posted by Glen Bentley on
Friday, 16 January 1998, at 10:42 p.m.
1981 240DL Automatic Transmission CIS. The darn thing will start and run for 2 or three seconds then shut sown just like it run out of fuel. It will restart and shut down again. After 4 or 5 starts I can get it to keep running but very ragged until it warms up then it will run smooth. If the engine is shut down, it will restart fine while still warm but after a couple of hours and the engine is cold it is hard to start again. Any ideas??????
That sounds easy[ALL/1988] posted by Owen Woodland on
Saturday, 17 January 1998, at 3:26 a.m.
I had exactly the same problem.
It is due to the fuel pressure regulator being faulty (happens progressively).
The unit needs to be replaced (which takes a while). It is an octagonal unit, made by Bosch, located (on my '76 b21e at least) right near that rubber boot which goes over the air mass meter thingy. Cost me AU$165 to have one fitted, and that was second hand, the new ones are about AU$300 or so. (Gasp, and mine needs replacing again, only this time because it won't warm start properly).
Anyway, that's your problem, you can DIY, but the engine must be tuned up again at the same time, so it might be worth taking it to a mechanic for that at least (becase the CO level settings can go out of whack a bit)
Glad to be of service..
Owen in Australia
Re: 240 hard to start[ALL/1988] posted by Howard Berman on
Saturday, 17 January 1998, at 6:59 a.m.
Sounds like the cold auxiliary air valve. This unit allows more air into the system during cold start and warm up. It closes slowly over a few minutes as you warm up. If it does not work, your car does what you described.
Let me know if I'm right.
Howard Berman
91 740DL wagon 90K
84 260GL Diesel Wagon 190K
86 Peugeot 505DL Wagon 141K
83 Peugeot 505STI 70K
Re: 240 hard to start[ALL/1988] posted by Dave Stevens on
Saturday, 17 January 1998, at 2:11 p.m.
If Howard is right, the auxiliary air valve may be sticking shut. You can test this quite easily, before starting, tap solidly on the air valve a few times with a large screwdriver handle to see if that helps. Check the air valve passageway to see that it is open when cold (about 90% open) and when fully warm is about 90% closed. When closed, using a small screwdriver, you should be able to freely open the valve and it should close on its own. If this is the problem area then a thorough cleaning/lubrication of the air valve may help, but replacement is the the most expedient route.
If none of the above then it's back to being a fuel problem, either the control pressure regulator as suggested or even the fuel pumps.
Re: 240 hard to start[ALL/1988] posted by Mark Klein on
Saturday, 17 January 1998, at 5:31 p.m.
Sounds like a fuel pressure problem more than an air regulator problem. The air regulator, as someone stated, is free and easy to visually inspect. If this is okay, I would have a full (thorough) fuel pressure test done.
Re: 240 hard to start[ALL/1988] posted by Jim Hekker on
Sunday, 18 January 1998, at 3:18 a.m.
The cold start injector supplies extra fuel into the intake manifold while the starting motor is operating. When the engine starts the cold start injector stops and the engine has to rely on the fuel pressure built up in the system. If the pressure is not right the engine stops. Exactly the same thing happened with one of our 240s and after trying all options I found that the fuel pressure regulator was faulty (by swapping components from between our 240s.) After installing a new pressure regulator the problem was solved. If you are not sure, get the fuel pressure checked out by a specialist first.
Re: 240 hard to start[ALL/1988] posted by Lee on
Tuesday, 20 January 1998, at 8:24 p.m.
I had the same symptoms occuring with our '81 745 two years ago and, after much aggravation, found the problem to be the fuel accumulator. I hate to add another device to check to the excellent list of checks by the other follow-ups, but fuel supply/air control problems are some of the hardest to root out. If a fuel pressure test is done, keep the pressure guage in the system for a long period of time (hour or two?)and then crank the engine again. If it takes a couple of seconds for the fuel pressure to build up to the static pressure (43psi?), then your problem could very well be the accumulator. It is found connected in parallel with the fuel pump and is needed to "hold" fuel pressure in the lines to the fuel distributor when the car is not running.
Good luck!
Re: 240 hard to start[ALL/1988] posted by Mike Jordan on
Sunday, 18 January 1998, at 10:47 a.m.
Check the cold start injector first. Pull it out of the manifold with the
engine cold.Disconnect the electrical connector. Connect a test lite to
the connector and crank the engine. No lite-repeat with the other side
of the connector. You should have a lite with one of them. If not you have
a fault with the wiring or the temperature sensor. If you have a lite,
then test the cold start injector. Key on- jump fuse #5 to fuse #7 to
make the fuel pump run. Then place the cold start inector in a small jar.
Jump one injector terminal to ground and use your test lite to power up
the other terminal from battery + . It should spray. If not , replace it.
Your symptoms are classic for a non-functional colld start injector.
Re: 240 hard to start[ALL/1988] posted by Skip on
Tuesday, 20 January 1998, at 7:50 p.m.
If the problem is worse on cold mornings and better on warm mornings, it's classic control pressure regulator failure. Replacement is only fix.