Need ECC/Blower Fan/A/C HELP!!! 850 1995

Well, start with checking all of those fuses to start. Those relays are located next to the fuses in the underhood compartment. You would have to shoot the 4 screws that hold the entire cover down out of the way and then you can access it. They are overload relays and I doubt they are the problem but they are part of that circuit. They hot up, among other things, the ECC ECU (via fuse 31) and fuses 12 and 13. The actual compressor relay is located on the front of the climate control box behind the glove box. Usually relays aren't the culprit in what you describe. It sounds as if your compressor shorted to ground and popped a fuse. The question is while it was shorted to ground did it draw enough current to smoke your ECU. From the schematic it looks like it would be tough to do, but you never know.

Mark






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New Need ECC/Blower Fan/A/C HELP!!! [850][1995]
posted by  95_850_Turbo  on Thu Apr 28 02:28 CST 2005 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.