Volvo RWD 700 Forum

INDEX FOR 10/2025(CURRENT) INDEX FOR 12/2002 700 INDEX

[<<]  [>>]


 VIEW    REPLY TO THIS MESSAGE Replies to this message will be emailed.    PRINT   SAVE 

No Start - Power Stage - Testing & Connector Pin Voltages 700 1989

89 760T - No Start Condition. Bosch EZK Ignition. No Spark from coil when grounding HT wire. Test light on (-) coil terminal produces steady light and does not flash (no ground impulses) when cranking engine.

Coil has good voltage on both LT terminals with key on. Coil LT and HT resistance checks within spec.

Power stage connector term 2 (ground) and terms 1 & 4 (battery with key on) measure good. Terminal 5 measures 0.0-0.5 Volts (while cranking engine) with a digital multimeter. Volvo Problem Solver indicates term 5 should be oscillating between approximately 0.8-1.2 Volts.

Per Solver, if voltage is oscillating and coil does not fire, power stage is bad. If not oscillating, check hall sensor.

My question is does anyone have experience with measuring term 5 on the Power Stage connector? In other words, would 0.0-0.5V (with digital multimeter) be considered within normal range and enough to trigger the power stage?

Thanks
--
dnvolvo 89 765T 200k - 91 245 100k






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New No Start - Power Stage - Testing & Connector Pin Voltages [700][1989]
posted by  dnvolvo  on Wed Jan 4 15:20 CST 2006 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.