AC Pressure readings and recharge 850 1994

You need to add refrigerant. Put in a pound or less and check it. Your low side pressure should be in the area of 30-35 pounds and fairly steady. The compressor keeps cutting in and out because it is low on refrigerant. When the compressor pulls the low side down to less than 30 or so it cuts out and when the pressure creeps back up to 45 or so it will rengage. If you have enough refrigerant in it that it cannot pull it down to less than 30 pounds then it will stay engaged like it should. If I am not evacuating the system I will usually meter in around 8 ozs. to 1lb. as I watch the pressures. If at one pound the pressures are stable and it blows cold I install some tracer dye in the system and ship it.






USERNAME
Use "claim to be" below if you don't want to log in.
PASSWORD
I don't have an account. Sign me up.
CLAIM TO BE
Use only if you don't want to login (post anonymously).
ENTER CAPTCHA CODE
This is required for posting anonymously.
OPTIONS notify by email
Available only to user accounts.
SUBJECT
MODEL/YEAR
MESSAGE

DICTIONARY
LABEL(S) +
IMAGE URL *
[IMAGE LIBRARY (UPLOAD/SELECT)]

* = Field is optional.

+ = Enter space delimited labels for this post. An example entry: 240 muffler


©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.