D-Type OD problem 120-130

Many possibilities for slipping.

Actuating pistons in upside down, wrong O-rings on the actuating pistons, clamping bars not fully seated, pump check ball or spring in wrong or damamged, pump body incorrectly positioned, relief valve spring weak or damaged. A small piece of dirt where it should not be in the fluid path after the pump pick up.

But I'd wager the most likely in this situation is the solenoid is out of adjustment. Solenoid adjustment is critcal with a very fine correctly adjusted linkage position. Requires a 3/16 inch drill bit and an amp meter capable of measuring 13 plus amps. Also this does not require the OD to come off to attempt correction.

I forwarded a diagram and instructions for solenoid adjustment to the e-mail address which the board provided with the question post.

Duane






USERNAME
Use "claim to be" below if you don't want to log in.
PASSWORD
I don't have an account. Sign me up.
CLAIM TO BE
Use only if you don't want to login (post anonymously).
ENTER CAPTCHA CODE
This is required for posting anonymously.
OPTIONS notify by email
Available only to user accounts.
SUBJECT
MODEL/YEAR
MESSAGE

DICTIONARY
LABEL(S) +
IMAGE URL *
[IMAGE LIBRARY (UPLOAD/SELECT)]

* = Field is optional.

+ = Enter space delimited labels for this post. An example entry: 240 muffler


©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.