78 242 no start (long) 200

"...noticed that the contacts close when turning the key from ON to START, contacts do not close until the starter is turning (is this normal?)"

• Yes, for safety reasons, no Fuel operation can start (or continue) without detecting ignition pulses from Coil #1.


"-Jumpered it with a Y cable (jumpered with open relay plogged in, with Y cable going between #30 and #87a & #87b)...both pumps working when jumped but car will not start."

• That suggests an ignition problem. Your Y jumper should work fine as a relay substitute, as long as all 3 contacts were good. (I have one made up with flat spade terminals that plug into the harness with the relay removed.)
--
Bruce Young
'93 940-NA (current), 240s (one V8), 140s, 122s, since '63.






USERNAME
Use "claim to be" below if you don't want to log in.
PASSWORD
I don't have an account. Sign me up.
CLAIM TO BE
Use only if you don't want to login (post anonymously).
ENTER CAPTCHA CODE
This is required for posting anonymously.
OPTIONS notify by email
Available only to user accounts.
SUBJECT
MODEL/YEAR
MESSAGE

DICTIONARY
LABEL(S) +
IMAGE URL *
[IMAGE LIBRARY (UPLOAD/SELECT)]

* = Field is optional.

+ = Enter space delimited labels for this post. An example entry: 240 muffler


©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.