Testing the resistance of defogger grid 140-160

Al;

You certainly could use the power-up technique...as far as measuring resistance goes, I expect something under 10 Ohms or so...after all, it's just multiple tiny micro-gauge wires in parallel...at 12Ohms, 1 Amp would pass and dissapate only 12Watts total (I don't think that would defrost a window too effectively)...at 1.2Ohms, 10 Amps would pass and result in 100Watts (that's a bit toasty!), so I expect something between the two, but this is strictly my off the cuff estimate... I hope it helps a little.

Cheers






USERNAME
Use "claim to be" below if you don't want to log in.
PASSWORD
I don't have an account. Sign me up.
CLAIM TO BE
Use only if you don't want to login (post anonymously).
ENTER CAPTCHA CODE
This is required for posting anonymously.
OPTIONS notify by email
Available only to user accounts.
SUBJECT
MODEL/YEAR
MESSAGE

DICTIONARY
LABEL(S) +
IMAGE URL *
[IMAGE LIBRARY (UPLOAD/SELECT)]

* = Field is optional.

+ = Enter space delimited labels for this post. An example entry: 240 muffler


©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.