Warm Start Trouble 140-160

Heat soak is not likely the problem. I've seen several variants on this:

Electric choke doesn't work (on models that have an electric choke) or is misadjusted. Pop the air cleaner off and watch it following a cold start -- the butterfly at the top of the carb should be completely vertical after two or three minutes.

Choke linkage disconnected (on both electric and manual choke models). The rod that operates the choke butterfly loses its tiny retaining clip and comes loose, so the butterfly stays closed when it shouldn't.

Excessive fuel pressure over-riding the floats. This should be 4 PSI or less. This has to be checked with a gauge.






USERNAME
Use "claim to be" below if you don't want to log in.
PASSWORD
I don't have an account. Sign me up.
CLAIM TO BE
Use only if you don't want to login (post anonymously).
ENTER CAPTCHA CODE
This is required for posting anonymously.
OPTIONS notify by email
Available only to user accounts.
SUBJECT
MODEL/YEAR
MESSAGE

DICTIONARY
LABEL(S) +
IMAGE URL *
[IMAGE LIBRARY (UPLOAD/SELECT)]

* = Field is optional.

+ = Enter space delimited labels for this post. An example entry: 240 muffler


©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.