"i did not get 12v at cps connection,if i tested it correctly,ign. on,lead to #3 terminal,neg to ground."
There is no voltage at the CPS connection until the sensor generates the signal to the EZK ICU. But as others have said, if you have spark at the plugs, the CPS must be working.
Below is a sequenced list of the main steps for starting and running:
Start-Run Sequence LH2.4 or REX
1) During starter cranking, the Crank Position Sensor sends timing pulses to Ignition Control Unit (ICU = EZK or REX)
2-a) The ICU uses these CPS pulses to trigger the Power Stage (aka Ignition Amplifier), which initiates spark from the coil.
2-b) At the same time, The ICU also propagates the pulses to the FI ECU, to allow FI operation (no ICU pulses means no FI operation).
3-a) The Fuel Injection (System)* relay (previously energized at Key On) powers the AMM, IAC, ECU, Injectors, and Fuel (pump) relay coil + side.
* The System relay is in the white case with the Fuel relay.
3-b) When ICU pulses are received by the FI ECU, it "energizes" the Fuel relay by grounding the relay coil (– side) to run the fuel pumps.
When all these things work, the engine runs until the Ignition is switched off, which in turn shuts down the FI system.
Determining whether or not there is spark at the plugs (2a) — and whether or not the plugs are getting gas (3b) — makes a good no-start "starting" point.
For example, if 2a fails due to a bad Power Stage/Amplifier, there will be a no-start with gas-wet plugs. If 2b fails (practically never) symptoms will be Fuel-related: a no-start with spark at the plugs, but plugs remain dry.
--
Bruce Young, '93 940-NA (current), 240s (one V8), 140s, 122s, since '63.
|