Blower Motor Changed / Air Con No Longer Works 200 1992

Joe,

Most often post fan replacement problems are due to disconnected ground wires that go to the floor/tunnel. It is also possible that a leak developed in the AC system resulting in the loss of refrigerant. The AC delay relay is on the right side of the console just behind the control panel.

To force the compressor to start, disconnect the wire coming from the compressor (green I think) and jumper it to the positive terminal of the battery, this engages the compressor. Start the car and see if the AC blows cold inside the car, if so, the refrigerant level is probably okay.

Report back with findings.

jorrell
--
92 245 317K miles, IPD'd to the hilt, 06 XC70, 00 Eclipse custom Turbo setup...currently being enjoyed!






USERNAME
Use "claim to be" below if you don't want to log in.
PASSWORD
I don't have an account. Sign me up.
CLAIM TO BE
Use only if you don't want to login (post anonymously).
ENTER CAPTCHA CODE
This is required for posting anonymously.
OPTIONS notify by email
Available only to user accounts.
SUBJECT
MODEL/YEAR
MESSAGE

DICTIONARY
LABEL(S) +
IMAGE URL *
[IMAGE LIBRARY (UPLOAD/SELECT)]

* = Field is optional.

+ = Enter space delimited labels for this post. An example entry: 240 muffler


©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.