The message to which you are about to reply is shown first. GO TO REPLY FORM
posted by
someone claiming to be abe crombie
on
Thu Jul 16 17:54 CST 1998 [ RELATED]
|
|
ICQ>
93 and later models that have R134A refrigerant as factory fill have a compressor high temp shutdown switch at compressor clutch circuit on comp.
This can make compressor go off for 5-10 minutes if one of two things is happening:
1. refrigerant level is getting low. The unboiled refrigerant on a full system that returns to compressor will cool it. If it's low this doesn't occur and off it goes.
2. If it's over 100 F outside the a/c shutdown will occur due to compressor getting too hot. You can prevent this manually selecting recirc when it's this hot as the recirculated air entering evaporator will allow the return refrigerant back to compressor to coll it down enough to prevent this. Don't let it stay on recirc forever as this will lead to a much increased likelihood of a/c odors. Turn it off recirc at night or when the temp gets back to normal (if it ever does in TX)o
|
|
* = Field is optional.
+ = Enter space delimited labels for this post. An example entry: 240 muffler
©Jarrod Stenberg 1997-2022. All material except where indicated.
Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.