Trouble shooting a Noisy starter - electrical info needed. 700 1991

Howdy,

I replaced a very noisy and eventually non functioning starter with a new (rebuilt)one, which starts the car but is also very noisy (and gets hot) after ignition.

I assume that the starter pinion gear is not disengaging from the flywheel gear.

Before writing off and removing the 2nd starter, I am trouble shooting the electrical control of the starter.

From the green wiring book, I assume that the terminal lead (small blue-green wiring attaching to the solenoid via a clip connector) is what controls the advancing and retracting of the pinion gear.

I measured 0 volts here in key position I , and 12 volts in KP III as expected, but also 12 v in KP II.

Can anyone confirm if my findings are abnormal (the 12 v on the terminal lead in KP II) and suggest a cause?

Would the fault be at the ignition switch??

Any input welcomed.






USERNAME
Use "claim to be" below if you don't want to log in.
PASSWORD
I don't have an account. Sign me up.
CLAIM TO BE
Use only if you don't want to login (post anonymously).
ENTER CAPTCHA CODE
This is required for posting anonymously.
OPTIONS notify by email
Available only to user accounts.
SUBJECT
MODEL/YEAR
MESSAGE

DICTIONARY
LABEL(S) +
IMAGE URL *
[IMAGE LIBRARY (UPLOAD/SELECT)]

* = Field is optional.

+ = Enter space delimited labels for this post. An example entry: 240 muffler


©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.