hi again,
the power stage is the unit that controls the fan speed by limiting the amount of current that the fan motor recieves. it is a aluminium heatsink housing with a transistor mounted in the middle of it and has a black three pin electrical connector on the bottem of it. its mounted in the air ducting next to the fan motor but all you can see of it from below is the plug connector you have to undo 2 phillips screws to remove it.
im afraid it cant really be tested however if there is power and an earth going to it and the fan doesnt run then its usually the problem,if you had access to another good unit you could try swap them and check this.
good luck.

steve.






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New 2001 volvo s40 heating blower problem
posted by  someone claiming to be zagi  on Mon Feb 14 07:14 CST 2005 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.