Generator test - 2nd try
Resistance readings in ohms - three broken generators
Generarot 1
Df to D- Zero through 180 degrees rotation
D+ to D- Zero through 180 degrees rotation
Df to D+ Zero through 180 degrees rotation
Generator 2
Df to D- Infinite 0 through 105 degrees rotation;
30 ohms at 110 degrees rotation;
infinite 115 degrees through 225 degrees;
zero at 190 degrees
infinite at 200 through 220 degrees
zero at 230 dgrees
infinite from 240 though 260 degrees
zero at 270 degrees
infinite from 280 degrees to 360 degrees
D+ to D- Infinite 0 through 105 degrees rotation;
40 ohms at 110 degrees rotation;
infinite 115 degrees through 225 degrees;
zero at 230 dgrees
infinite from 240 though 260 degrees
zero at 270 degrees
infinite from 280 degrees to 360 degrees
Df to D+ zero through 180 degrees rotation
Generator 3
Df to D- Infinite through 180 degrees rotation
D+ to D- Infinite through 180 degrees rotation
Df to D+ Infinite through 180 degrees rotation
I'll try to get readings on my good installed genny in the next couple of days.
Best regards,
Joe M
|