Correction 200 1990

As with any confident statement, the fallacy soon comes to mind.

"The low voltage you saw at the AMM cannot have been caused by a poor ground at the fuel rail."

The meter could have displayed ~8 volts if the relay was buzzing at the time. If it is buzzing, the 12 volt source is interrupted rapidly and the meter will display what amounts to be an average of its samples. And the poor ground at the rail can cause the relay to buzz.

So if you remember the sound of the relay buzzing when you measured the voltage at the relay socket, then you can assume the rail ground cleanup took care of that.
--
Art Benstein near Baltimore

Artificial intelligence is no match for natural stupidity.






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New 1990 - no start but cranks - should FI relay click with ignition? [200]
posted by  transit wind subscriber  on Fri Aug 17 15:21 CST 2018 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.