ICU 'Switching Function' failed 200 1984

"...using a test lead I jumpered the B and C terminals in the harness connector according to fig. 15 in the book and repeatedly installed them and removed them. I am not getting any spark."

Charles, I'm afraid my hasty read of that Bentley test sequence caused me to overlook the obvious:

If the ICU can't do its thing with a simulated (Hall Sensor) signal, there is no point in testing the HS itself. It's a 2-step process:

1) Hall Sensor signals ICU that it's Spark Time

2a) ICU removes ground from Coil 1
2b) Coil then generates spark voltage to distributor center wire
2c) ICU also pulses FI ECU, allowing fuel pumps etc.

The B-C jumper simulates Step 1, if step 2 then fails, the (disconnected) Hall sensor wasn't even present, so there's no reason (yet) to suspect it.

See the NOTE below step 6. It assumes the B-C simulation worked, and thus leaves you hanging if it didn't. For now I must do the same. In the meantime I suggest you start a new post/thread, beginning with a concise summary of what was learned from this one.

I'll be watching.


--
Bruce Young
'93 940-NA (current), 240s (one V8), 140s, 122s, since '63.






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New Coil question for my diesel to gas car conversion [200]
posted by  volvo245kit  on Sun Apr 20 10:31 CST 2008 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.