244 electrical problem...fuse melted? 200 1984

i only read the first paragraph because the fuse powers the fuel pump relay and the fuel system relay in the 83-84 240. replace the fuse holder and make sure the connections are tight. the 2 relays are under the glovebox. i'm betting the supply from the fuse or the supply to the fuel pump-yellow/red is loose or melting out of the relay socket. once everything is squared away, check the current draw, could be the main pump is dying and drawing too many amps or the tank pump has died and the main pump is suffering from fuel starvation.

there may be other problems in the car. too early too tell. good luck, chuck.






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New 244 electrical problem...fuse melted? [200][1984]
posted by  Sanfam  on Sun Mar 7 14:46 CST 2004 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.