240 Fuel Problems (Long response again) 200 1986

Sorry for the delay, I took a short vacation. I checked the items as you described.
A) The Terminal 30 is hot all the time (from the 25 amp fuse).
B) 12V is available at #30 and is present on 86/1 terminal. 12 volts go through the relay and are present at 86/1.
C) The Key is turned on. The 86/1 terminal goes from 12v to 0v as you described the coil is energized.
D) The Main relay actuates and stays closed.

I then went on to check for resistance, I unplugged the relay and probed the 86/1 connector, connected the other lead on the meter to a good ground as you discussed. It displayed "No Continuity" or "Out of Range" indication on the meter with the key off. I turned the key on... The meter did not go to 0 ohms, it remained "out of range", I checked to make sure I had good ground and good connection at the connector, it remained "Out of Range." Does this mean that the ECU is defective? Thanks for walking me through this, David..






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New 1 Volvo 240 fuel pump wiring troubles... [200][1986]
posted by  dave-ed  on Tue Oct 5 19:10 CST 2004 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.