760 coil testing 700 1984

The needle was going back and forth pretty drastically. Maybe this is the grounding/ungrounding you're talking about?

Yes, probably the neg terminal was going + and - as the powerstage pulsed the coil. I which case you should see a spark from the coil wire to ground (with a gap of about 1/4" or so).

With the meter on the + terminal and the Key on II, the meter should read a steady +12, or whatever the battery is currently at. No reason for it to "go crazy", except maybe some pulsing when cranking starts. I'm not sure about that though.
--
Bruce Young
'93 940-NA (current) — 240s (one V8) — 140s — 122s — since '63.






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New 760 turbo won't start...Save it from the junkyard! [700]
posted by  mikeb23ft  on Tue Feb 1 10:02 CST 2005 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.