740 non runner 700 1986

I think you are referring to the radio supression relay, RSR. This is located on a bracket of the coolant reservoir. Could be that there is a second relay there also. If so, this is for the electric fan. Not sure if you have one on '86 car.

The RSR provides the power to the fuel injectors. Relays and solenoids clicking on and off can cause quite a bit of radio "noise". By providing power by an underhood relay, much of the noise is isolated from the other circuits. Check to see if you can hear the injectors ticking as you crank the engine. If so, this is not the cause.

Another likely cause is the hall sensor in the distributor. This sensor provides an input to the ecu that is used to enabe ignition system. The fuel pump relay is actualy two relays. The first is the system relay and is activated by the key in the run position, and the second is activated when the ecu receives pulses from the hall sensor. This second relay energizes the fuel pumps.

Good luck,

Dan






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New 740 non runner [700][1986]
posted by  someone claiming to be Tony  on Sat Sep 20 22:51 CST 2003 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.